Prepare 5V0-21.21 Question Answers - 5V0-21.21 Exam Dumps [Q26-Q50]

Share

Prepare 5V0-21.21 Question Answers - 5V0-21.21 Exam Dumps

Real VMware 5V0-21.21 Exam Questions [Updated 2021]


VMware 5V0-21.21 Exam Syllabus Topics:

TopicDetails
Topic 1
  • VMware Products and Solutions
  • Given a scenario, identify the VMware products and solutions that will interact with a vSAN solution
Topic 2
  • Given a scenario, identify the implications of integrating VMware solutions with vSAN
  • Installing, Configuring, ana Setup
Topic 3
  • Given a scenario, identify how to apply the appropriate maintenance mode option
  • Given a scenario, identify the apDropriate action to recover from a vSAN or infrastructure failure
Topic 4
  • identify the appropriate action to troubleshoot performance issues in a vSAN deployment
  • Identify vSAN data placement changes (stretches clusters, fault aomains)
Topic 5
  • identify the tasks to manape a stretches vSAN cluster
  • Identify the operational tasks required to manape an encrypted vSAN
Topic 6
  • Performance-tuning, Optimization, Upgrades
  • Given a scenario, identify the appropriate vSAN upgrade methodology
Topic 7
  • Given a scenario, identify the implications of integrating VMware solutions with vSAN
  • Given a scenario, identify the use cases for an HCI Mesh infrastructure

 

NEW QUESTION 26
for a customer who is planning to use vRealize Automation to provision 600 virtual machines into that cluster, with expected growth up to 1,000 VM. Each VM has a 40GB thick-provisioned disk.
Which flash disk size is required for the cache tier per ESXi node to meet all requirements?

  • A. 800GB
  • B. 600GB
  • C. 700GB
  • D. 400GB

Answer: A

 

NEW QUESTION 27
An administrator is tasked to create a custom storage policy for workloads and is including additional disk stripes while defining the storage policy.
What is the main purpose of this practice?

  • A. To set a failure tolerance
  • B. To reconstruct corrupted data
  • C. To increase available storage space
  • D. To improve performance

Answer: A

 

NEW QUESTION 28
An administrator is tasked with migrating a VMware Horizon View environment that is currently running on an NFS Datastore to VMware vSAN.
Which Horizon configuration option will not be available when configuring vSAN in Horizon View?

  • A. Instant Clones
  • B. Linked Clones
  • C. Storage Profiles
  • D. Storage Tiers

Answer: D

 

NEW QUESTION 29
Due to the success of the recently deployed developer-only private cloud solution, a company has a new requirement to at least double the usable capacity in their all-flash vSAN cluster.
The vSAN cluster is deployed into a co-located datacenter that is owned by a third-party hosting company. The hosting company charges a fixed monthly cost for rack space and power consumption. The service owner has been given a limited budget for additional hardware purchases, but not for on-going co-location costs.
The current vSAN cluster has the following configuration:
* 10 vSAN Nodes with 2 CPUs (20 cores), 512 GB RAM
* 1 Disk Group per vSAN node
- 1 x 400 GB
- 4 x 1.8 TB
* De-duplication and Compression is enabled.
* vSAN Capacity is currently:
- Total: 72 TB
- Usable: ~40 TB (FTT1/RAID1) and ~60 TB (FTT1/RAID5).
As a result of any action taken, the service owner would like to ensure that overall availability of the vSAN cluster is increased.
Which two recommendations meet the requirement to increase capacity while maintaining service availability? (Choose two.)

  • A. Install an additional 400 GB SSD and 4 x 1.8 TB SSDs per vSAN node.
  • B. Create a new Disk Group, and claim the newly installed cache and capacity SSD drives for each node.
  • C. Install an additional 3 x 1.8 TB SSDs per vSAN node.
  • D. Update the existing Disk Group, and claim the newly installed drives for each node.
  • E. Replace existing SSDs with an 800 GB SSD and 4 x 3.8 TB SSDs per vSAN node.

Answer: B,C

 

NEW QUESTION 30
An administrator has been tasked to reboot a node in an encrypted vSAN cluster. The vSAN disk groups on that node become locked after rebooting the node.
Which step should be performed to exit the locked state?

  • A. Run /etc/init.d/vsanvpd restart to rescan the VASA providers.
  • B. Replace the caching device in each affected disk group.
  • C. Restore the communication with the KMS server, and re-establish the trust relationship.
  • D. Manually replace the Host Encryption Key (HEK) of each affected host.

Answer: C

 

NEW QUESTION 31
An administrator is tasked with preparing for a Cross vCenter migration in a stretched vSAN cluster where the virtual machines migration will be orchestrated via VMware Site Recovery Manager.
Which action should the administrator take so the migration is successful?

  • A. Enable vCenter Single Sign-On Enhanced Linked Mode
  • B. Make sure that Witness traffic is on the management NIC.
  • C. Disable vSAN Deduplication and Compression
  • D. Reconfigure vCenter HA Admission control

Answer: A

 

NEW QUESTION 32
A company has engaged a consultant to upgrade an existing vSAN cluster to vSAN 7.0 U1. The company wants to ensure that the same vSAN process can be used in the future.
During the discovery phase, the consultant found the following information about the existing environment:
* The vCenter Server is currently version 7.0.
* The vSAN Cluster has the following configuration:
- vSAN version: 7.0
- Number of vSAN nodes: 6
- Encryption: enabled
- Deduplication and Compression: enabled
- Fault Domains: 1
- vSAN Capacity Utilization: 60%
* Each vSAN node has the following configuration:
- ESXi version: VMware vSphere 7.0
- CPU: 2 processors, 20 cores
- RAM: 1024GB RAM.
- Disk: 2 Cache SSDs and 6 Capacity SSDs
- Network: 4 x 10GbE
* All current hardware (which is from a single vendor) is listed on the vSAN Compatibility Guide for vSAN 7.
Which three recommendations should the consultant make to ensure that the vSAN cluster upgrade is completed? (Choose three.)

  • A. Upgrade all vSAN nodes to VMware vSphere 7.0 U1 using the images capability within VMware Update Manager (VUM).
  • B. Choose the Allow reduced redundancy option.
  • C. Set VMware Distributed Resource Scheduling (DRS) to partially automated.
  • D. Upgrade to VMware vCenter Server 7.0 U1.
  • E. Disable vSAN Encryption before starting the upgrade process.
  • F. Upgrade all vSAN nodes to VMware vSphere 7.0 U1 using the baselines capability within VMware Update Manager (VUM).

Answer: F

 

NEW QUESTION 33
An architect is designing a vSAN cluster.
Which storage controller option will yield optimal performance?

  • A. Hugh queue depth
  • B. Set caching to 50% read on the controller
  • C. RAID 0
  • D. Enable battery write-back caching

Answer: C

 

NEW QUESTION 34
An administrator is tasked with setting up Kerberos authentication only for the vSAN File services.
Which version of Kerberos must be selected if the NFS version is v4.1?

  • A. krb5
  • B. krb5i
  • C. krb5p
  • D. krb4

Answer: B

 

NEW QUESTION 35
An organization has two vSAN clusters managed by the same vCenter Server, each providing 100TB of storage. The first cluster runs at 75% of its storage capacity, and the second cluster runs at 50% of its storage capacity.
The company also has the following:
* An iSCSI array of 300TB. which runs at 76% of its capacity
* A NAS system of 200TB, which runs at 10% of its capacity
* A Fiber channel (FC) array of 300TB, which runs at 80% of its capacity The administrator is asked to add an additional 25TB of storage to the first cluster. The administrator is also made aware that there is no budget to purchase new hardware and that the vSAN Storage Policy Based Management must be kept in place.
Which storage option will work for this use case?

  • A. Obtain additional free capacity from the existing FC storage.
  • B. Create an HCI Mesh using the second cluster's datastore.
  • C. Create an HCI Mesh using the first cluster's datastore.
  • D. Obtain additional free capacity from the existing NAS storage.

Answer: D

 

NEW QUESTION 36
A customer has upgraded to vSAN 7, but there is still an existing legacy host which must be removed from the vSAN cluster.
Which three steps must an administrator take to successfully remove this host from the vSAN cluster? (Choose three.)

  • A. Delete the disk group(s) on the legacy host
  • B. Place the host in maintenance mode with no data migration
  • C. Place the host in maintenance mode with Ensure Accessibility
  • D. Disconnect from vCenter Server
  • E. Remove from vSAN cluster
  • F. Place the host in maintenance mode with Full Data migration

Answer: A,E,F

 

NEW QUESTION 37
An architect is designing for a production vSAN cluster, and the customer introduced these requirements related to File Services: A minimum of 12 files shares. 30TB NFS capacity to mount workload VMs.
What should be the architect's recommendations?

  • A. Point out the risks regarding putting the hosts in maintenance mode in terms of FSVM.
  • B. Highlight the required number of nodes required for the vSAN cluster as a constraint.
  • C. Confirm on all of the requirements and move forward with the physical design.
  • D. Raise concerns regarding support when running VMs on an NFS share as risk.

Answer: B

 

NEW QUESTION 38
A company hosts a vSAN 7 stretched cluster for all development workloads. The original sizing of a maximum of 250 concurrent workloads in the vSAN cluster is no longer sufficient and needs to increase to at least 500 concurrent workloads within the next six months.
To meet this demand, the original 8-node (4-4-1) cluster has recently been expanded to 16 nodes (8-8-1).
Which three additional steps should the administrator take to support the current growth plans while minimizing the amount of resources required at the witness site? (Choose three.)

  • A. Deploy a new large vSAN witness appliance at the witness site.
  • B. Configure the vSAN stretched cluster to use the new vSAN witness.
  • C. Deploy a new extra large vSAN witness appliance at the witness site.
  • D. Configure the new vSAN witness as a shared witness appliance.
  • E. Upgrade the vSAN stretched cluster to vSAN 7.0 U1.
  • F. Add the new vSAN witness appliance to vCenter Server.

Answer: A,B,D

 

NEW QUESTION 39
A company has deployed a 12-node (6-6-1) vSAN 7.0 stretched cluster for all production workloads.
The customer currently uses four different vSAN storage policies for running the workloads depending on the applications requirements:
* Policy 1 - Site Disaster Tolerance=Dual Site Mirroring, FTT=Erasure Coding
* Policy 2 - Site Disaster Tolerance=Dual Site Mirroring, FTT=Mirroring
* Policy 3 - Site Disaster Tolerance=None - Keep Data on Preferred, FTT=Mirroring
* Policy 4 - Site Disaster Tolerance=None - Keep Data on Non-Preferred, FTT=Mirroring During the setup of the vSAN stretched cluster, the following VM/Host Rules were created:
* Preferred Site - Preferred Site workloads should run on DC1 hosts.
* Secondary Site - Secondary Site workloads should run on DC2 hosts.
Which two activities should the administrator complete to ensure that there is no impact to production services during the maintenance window in the Preferred Site? (Choose two.)

  • A. Update vSphere DRS site affinity rules so that Preferred Site workloads must run on hosts in DC2.
  • B. Change the Site Disaster Tolerance setting in Policy 3 to be "Dual Site Mirroring".
  • C. Update vSphere DRS site affinity rules so that Preferred Site workloads should not run on hosts in DC1.
  • D. Change the FTT setting in Policy 3 to be "Erasure Coding".
  • E. Change the Site Disaster Tolerance setting in Policy 4 to be "None - Keep Data on Preferred".

Answer: A,E

 

NEW QUESTION 40
An administrator has an absent capacity disk.
Which action, if any, should the administrator take to resolve the problem?

  • A. Verify the host is not isolated.
  • B. Wait, and vSAN will rebuild it.
  • C. Replace the faulty disk.
  • D. Replace the faulty host.

Answer: B

 

NEW QUESTION 41
Upon checking the latency goal under vSAN performance diagnostics, the vSAN Administrator sees this message displayed:
The increase in latency in the vSAN stack might be beyond expected limits.
Which two root causes can be identified to help remediate the issue? (Choose two.)

  • A. Incorrect sizing of the disk groups capacity disks
  • B. vSAN VMKemel portgroup is configured with the "Route based on IP hash" teaming policy
  • C. vSAN encryption is enabled
  • D. Large packet losses and retransmissions on the network layer
  • E. One or more disk groups are congested

Answer: D,E

 

NEW QUESTION 42
A company has engaged a consultant to upgrade an existing vSAN cluster to vSAN 7.0 U1.
During the discovery phase, the consultant found the following information about the existing environment:
* The VMware vCenter Server has recently been upgraded from VMware vSphere 6.7 U3 to version 7.0 U1.
* The vSAN Cluster was recently expanded with identical hardware specification, but from a different hardware vendor.
* The hardware for each vSAN node is listed on the vSAN Compatibility Guide (VCG) for vSAN 7.
* The vSAN Cluster has the following configuration:
- vSAN version: 6.6.1
- Number of vSAN nodes: 10
- Encryption: enabled
- Deduplication and Compression: enabled
- vSAN Capacity Utilization: 60%
* Each vSAN node has the following configuration:
- VMware vSphere ESXi version: 6.5 Update 3
- CPU: 2 processors, 20 cores
- RAM: 768GB RAM.
- Disk: 2 Cache SSDs and 6 Capacity SSDs
- Network: 4 x 10GbE
Which three recommendations should the consultant make to ensure all data remains protected in the event of a vSAN failure? (Choose three.)

  • A. The vSAN nodes should be upgraded to vSphere ESXi 7.0 U1.
  • B. The Full data migration maintenance mode option must be chosen to protect the data during the upgrade.
  • C. The Ensure accessibility, migration maintenance mode option must be chosen to protect the data during the upgrade.
  • D. The upgrade process should be completed using host upgrade baselines in VMware vSphere Lifecycle Manager (vLCM).
  • E. The vSAN nodes should be upgraded to vSphere ESXi 6.7 U3.
  • F. The upgrade process should be completed using images in VMware vSphere Lifecycle Manager (vLCM).

Answer: A,C,F

 

NEW QUESTION 43
An administrator is setting up vSAN file services on a vSAN cluster.
Which two security policies on the distributed port groups are automatically enabled in the process? (Choose two.)

  • A. Promiscuous Mode
  • B. DVFiltering
  • C. MacLearning
  • D. Forged Transmits
  • E. Jumbo Frames

Answer: A,D

 

NEW QUESTION 44
A cache disk failure marked a vSAN disk group as failed, and the data is being rebuilt on other disk groups.
Which action should the vSAN administrator take to reduce the negative impact on the VMs?

  • A. Enabling Resync Throttling
  • B. Setting the vSAN policy's IOPS limit for object value to 0 (unlimited)
  • C. Enabling Maintenance mode with no data evacuation
  • D. Enabling automatic rebalance

Answer: A

 

NEW QUESTION 45
An architect is working with an All-Flash vSAN configuration and will be using the Flash Caching Devices in vSAN.
Which requirement is specifically needed for these devices?

  • A. Write endurance
  • B. Read endurance
  • C. Capacity
  • D. IOPS

Answer: A

 

NEW QUESTION 46
......

5V0-21.21 Exam Dumps Pass with Updated 2021: https://www.validdumps.top/5V0-21.21-exam-torrent.html

Free 5V0-21.21 Exam Dumps to Pass Exam Easily: https://drive.google.com/open?id=11mfq4iy2h3eZWAn7q1tgIQRFkMqZRUfa