NEW QUESTION 36
Exhibit:

You have FCoE configured between your Nexus 5672UP switches and UCS Fabric Interconnects running in FC end-host mode. You are experiencing disk I/O errors on your VMware FCoE datastore, but the NFS data stores on the same NetApp storage system are not exp eriencing any problems.
Referring to the Nexus output shown in the exhibit, what would cause this problem?

  • A. Port flow-control is currently off.
  • B. "VL bmap" is hard to set to "off".
  • C. The no-drop QoS classes on the Fabric Interconnects are different than those on the Nexus switches.
  • D. The FCoE uplinks from the Fabric Interconnects must use the ports on the far right side of the Nexus switches.

Answer: C

 

NEW QUESTION 37
Exhibit:

Referring to the exhibit, what do the asterisks on the left indicate about the output of the ~show zoneset active~ command?

  • A. The device is currently logged in.
  • B. The device is not currently logged in.
  • C. A redundant path is present.
  • D. Only a single path is present.

Answer: A

 

NEW QUESTION 38
For a 'boot from SAN' configuration, which two features must be enabled? (Choose two)

  • A. FCOE
  • B. UDLD
  • C. FCSP
  • D. NPIV
  • E. FC
  • F. VPC

Answer: A,D

 

NEW QUESTION 39
Which three are types of Storage Virtual Machines? (Choose three.)

  • A. cluster
  • B. intercluster
  • C. node
  • D. data
  • E. flex
  • F. vFiler

Answer: A,C,D

 

NEW QUESTION 40
When installing an instance of VMware ESXi on a UCS B-Series server, where should an ISO image be loaded?

  • A. Only physical install disks are supported on UCS B-Series servers
  • B. The UCS vCenter Plugin must be used
  • C. ISO images should not be used
  • D. From the UCS Manager select KVM Console, Select the Virtual Media tab, and select Add Image

Answer: D

 

NEW QUESTION 41
Which two statements about HA pairs in a NetApp cluster are true? (Choose two.)

  • A. HA pairs in the same chassis are not connected to each other through an HA interconnect.
  • B. Non-disruptive aggregate relocation can be performed between HA pairs without a takeover and giveback.
  • C. In the event of a storage failover, the surviving node provides read/write access to the partner's disks until the failed node becomes available again.
  • D. In the event of a storage failover, the surviving node always takes over the partner's data LIFs.

Answer: C,D

 

NEW QUESTION 42
Which two LIFs are able to failover or migrate to other nodes in the cluster? (Choose two.)

  • A. data LIF of protocol iSCSI
  • B. intercluster LIF
  • C. node management LIF
  • D. data LIF of protocol NFS
  • E. data LIF of protocol FCoE
  • F. data LIF of protocol CIFS
  • G. cluster LIF

Answer: F,G

 

NEW QUESTION 43
Where are log files located on a NetApp node?

  • A. /mroot/etc/crash/
  • B. /log/core/
  • C. /etc/mlog/
  • D. /letc/log/crash
  • E. /mroot/etc/log/mlog/

Answer: E

 

NEW QUESTION 44
An administrator has a FlexPod solution using VMware vSphere 6.0. The ESXi hosts use iSCSI for storage connectivity, and all paths have been configured and connected between the NetApp cluster and the ESXi hosts.
Virtual Storage Console has been installed and ESXi host-recommended settings have been applied to all hosts. The active LUN path for one of the iSCSI datastores experiences a connectivity failure and the LUN switches to a new active path.
In this scenario, which event would trigger the ESXi host to switch the active LUN path again?

  • A. The host processes 1,000 I/O operations.
  • B. The original LUN path comes back online.
  • C. The NetApp LIF is reverted to its home port.
  • D. The ESXi host scans for new VMFS datastores.

Answer: C

 

NEW QUESTION 45
How many ACTIVE SPAN sessions exist on a Fabric Interconnect?

  • A. 0
  • B. 1
  • C. 2
  • D. 3
  • E. 4

Answer: D

 

NEW QUESTION 46
Which endpoint's firmware can be directly upgraded (without the use of a Service Profile) using UCS Manager?

  • A. RAID Controller
  • B. CIMC
  • C. HBA
  • D. BIOS

Answer: B,D

 

NEW QUESTION 47
Which type of pools do you need to create vHBA templates?

  • A. MAC
  • B. WWPN
  • C. WWNN
  • D. IQN

Answer: B

 

NEW QUESTION 48
Exhibit:

You just configured a new Storage Virtual Machine named SVM1 on your NetApp cluster to serve up NFS datastores to an ESX cluster.
Your VMware administrator tells you that the ESX servers are unable to access the datastore that you created on node flexpod1-san01-01. The IP address of one of the ESX servers is 10.33.128.100.
Referring to the exhibit, which command would you use to troubleshoot this problem?

  • A. ~network ping -lif nfs1 -vserver svm1 -destination 10.33.128.100~
  • B. ~network ping -node flexpod1-san01-01 -destination 10.33.128.100~
  • C. ~network ping -lif cluster mgmt -vserver flexpodl-san01 - destination 10.33.128.100~
  • D. ~network ping -lif flexpod1-san01-01 mgmt1 -vserver flexpod1-san01 -destination 10.33.128.100~

Answer: A

 

NEW QUESTION 49
Exhibit:

An iSCSI SAN boot is not working for a new Cisoc UCS service profile. The new vNIC template was created using the settings shown in the exhibit.
What should you do to make iSCSI SAN boot work?

  • A. Change the MAC pool to "<not set>".
  • B. Specify a QoS policy.
  • C. Set the iSCSI-A-VLAN as the "Native VLAN".
  • D. Change the vNIC template to type "Initial Template".

Answer: B

 

NEW QUESTION 50
You are attempting to establish a cluster peer relationship between two NetApp clusters, but the peering process fails.
What is a cause for this failure?

  • A. The cluster management LIF for the cluster cannot communicate with the cluster management LIF for the peer cluster.
  • B. The node management LIF on each node cannot communicate with the node management LIF on each node in the peer cluster.
  • C. The cluster LIFs on each node cannot communicate with the cluster LIFs on each node in the peer cluster.
  • D. The intercluster LIF on each node cannot communicate with the intercluster LIF on each node in the peer cluster.

Answer: D

 

NEW QUESTION 51
While working on a performance related issue on your FlexPod solution, you notice an unequal distribution of traffic over the physical interfaces of a four port vPC between two Nexus 5000 switches. You would prefer a more even traffic distribution.
Which command would you use to accomplish this task?

  • A. ~hardware multicast hw-hash~
  • B. ~lacp system-priority~
  • C. ~lacp rate fast~
  • D. ~port-channel load-balance ethernet~

Answer: D

 

NEW QUESTION 52
How many VEMs can one server have?

  • A. unlimited
  • B. 0
  • C. 1
  • D. 2

Answer: D

 

NEW QUESTION 53
Which two technologies must be deployed for a Cisco Nexus 9000 ACI design? (Choose two.)

  • A. VSM
  • B. LACP
  • C. spine switch
  • D. APIC

Answer: C,D

 

NEW QUESTION 54
The NetApp Vistual Storage Console is used to set which three setting categories on ESXi hosts? (Choose three.)

  • A. Logging Settings
  • B. Security Settings
  • C. MPIO Settings
  • D. Adapter Settings
  • E. NFS Settings

Answer: C,D,E

 

NEW QUESTION 55
Which of the following tools is designed to inventory existing VMware vSphere, Linux, and Microsoft Windows Server versions in a customer environment?

  • A. Microsoft Assessment and Planning (MAP) Toolkit
  • B. Cisco Resource Comparison Tool
  • C. Cisco UCS Sizer for Enterprise Applications
  • D. Cisco UCS Central

Answer: A

 

NEW QUESTION 56
On a NetApp clustered Data ONTAP cluster, a volume named datastorel resides on an aggregate named node1 aggr1 and is mounted into the namespace at the junction path /esx cluster1/ds1.
A VMware virtual machine file named myhost.vmdk is at the root of the volume datastorel. A volume move operation relocates the datastorel volume to an aggregate named node3 aggr1.
In this scenario, what is the full path to the file myhost.vmdk after the volume move is complete?

  • A. /esx_cluster1/datastore1/myhost.vmdk
  • B. /esx_cluster1/ds1/myhost.vmdk
  • C. node3_aggr3/esx_cluster1/ds1/myhost.vmdk
  • D. /vo1/esx_cluster1/ds1/myhost.vmdk

Answer: B

 

NEW QUESTION 57
......

Network Appliance Practice Test Engine with NS0-176 Questions: https://drive.google.com/open?id=1RJDzqhkizN2AUb2IVgPbBx91UTxXD-Hm

Guaranteed Success with Valid Network Appliance NS0-176 Dumps: https://www.validdumps.top/NS0-176-exam-torrent.html